650.237.0155
E-Mail
Home
Products
Applications
Technology
Technical Support
Software
News & Events
About Us
Contact Us
Contact Information
Request for Quote
Medical &
Healthcare
O2
O2T - O2TR
O2CAP
Oxygen
Deficiency
Monitor
O2iM
Industrial
Process
O2iL - O2iC
O2E - O2E2
O2C - O2D
O2L
Aerospace
O2N2
Laboratory &
Research
O2C/D
O2L
O2Cap - (B/D)
O2iR
O2Bio
O2Mix
Exercise Test / Kona
Tabletop
O2
O2L
O2C/D
O2Cap (B/D)
O2T - O2TR
NEMA 4x
O2iM
O2iL - O2iC
O2E - O2E2
OEM
Search Catalog
By Keyword
By Item #
All Categories
O2C , O2D and O2DAL Oxygen Analyzers
All Categories
>
Oxygen Analyzers by Products
>
O2C , O2D and O2DAL Oxygen Analyzers
>
Item # 07-7016
Download PDF
Download PDF
Printable Page
Email This Page
Save To Favorites
Please wait…
Item # 07-7016, Model O2DAL, Oxygen, Single Channel, Table Top
larger image
The Model O2DAL is a general purpose oxygen analyzer for research, air separation monitoring, and industrial monitoring applications. The Model O2DAL is designed to measure oxygen in a range of 5-100% levels and operates in XC and LN mode for reliable measurements in the presence of other gases including Ar, He, H2, CO2 and non-condensing H2O vapors. The Model O2DAL features an easy to use and bright LED display, touch panel controls, easy calibratiom, and has a high flow micro pump for low pressure operation from 1200 to 55mbar (0-60,000 feet altitude) and internal flow meter for monitoring flow in the system. A terminal strip on the rear panel is included for analog relay alarm outputs , 4-20 mA outputs, and an analog 0-1.0 VDC output is on a BNC connector. A DB-9 connector RS-232 digital output provides digital serial communications and is compatible with Oxisoft software. The unit has CPC O-ring quick connect inlet fittings for industrial applications.
Performance Conditions
·
Performance Specifications
·
Electrical Specifications
·
Mechanical Specifications
Performance Conditions
Ambient Temperature (Operating)
5 to 40
ºC
40 to 105
ºF
Ambient Temperature (Storage)
-20 to 60
ºC
-2 to 140
ºF
Cell Pressure
2.2 to 17.4
psi
15 to 120
kPascal
112 to 900
mmHg
150 to 1200
Mb
Warm-up for Full Accuracy
10
min
Altitude
Two point calibration required after change in altitude of 2000 feet
Humidity
0 to 95%, non-condensing
Performance Specifications
Range
5 to 100%
Resolution
0.1%
Stability (24 hrs)
± 0.3%
Linearity
±0.2%
Cross Sensitivity
±0.2% in XC mode.
Input Pressure
-0.03 to 1.3
psi
Flow
0 to 250 ml/min pump on
50 to 500 ml/min pump off
Response Time
150 ms at 250 ml/min, electronic Filter setting 0 to 3
Alarms (4)
Low Flow
Oxygen A
Oxygen B
System Check
Relays
Form C (SPDT), 5 A, 250 VAC rating.
Analog Output
0 – 1 V, 1V = 100%.
4 – 20 mA programmable from front panel
Sample Inlet
CPC O-ring quick connects, 1/8 “ flex tubing barbs std.
Electrical Specifications
Sensor Power Requirements
0.8 A typical
12 ± 0.6 VDC
2.5 A max
External Power Supply
100 to 250 VAC
47 to 63 Hz
Mechanical Specifications
Dimensions (W x H x D)
7.5x3.0x14.0
in
190x76x356
mm
Weight Instrument
4
Pound
1.8
Kilogram
DOWNLOADS
Fast Oxygen Analyzer O2C/D
(PDF, 111KB)
Options & Accessories (O2C & O2D)
Options & Accessories (O2C & O2D)
Site created by
Thomas Web Solutions