O2C , O2D and O2DAL Oxygen Analyzers


The Models O2C, O2D and O2DAL are general purpose oxygen analyzers for research, air separation monitoring, and industrial monitoring applications. Designed to measure oxygen in a range of 5-100% accurately and in the presence of other gasses such as including Ar, He, H2, CO2 and non-condensing H2O vapors. The Model O2C features an internal pressure regulator to connection to 1-75 psig source and the Model O2D features a sampling pump for flow control. The Model O2DAL features a high flow micro pump for low pressure operation from 1200 to 55mbar (0-60,000 feet altitude).



Items
01-0024
07-0158
O2C Oxygen, Single Channel, Table Top

01-0024
07-0168
O2D Oxygen, Single Channel, Table Top

O2DAL-Oxygen-Analyzer-OBOGS
07-7016
Model O2DAL, Oxygen, Single Channel, Table Top
Ambient Temperature (Operating)
5 to 40 ºC
40 to 105
ºF
Ambient Temperature (Storage)
-20 to 60 ºC
-2 to 140
ºF
Cell Pressure
10.2 to 17.4 psi
70 to 120
kPascal
500 to 900
mmHg
700 to 1200
Mb
10.2 to 17.4 psi
70 to 120
kPascal
500 to 900
mmHg
700 to 1200
Mb
2.2 to 17.4 psi
15 to 120
kPascal
112 to 900
mmHg
150 to 1200
Mb
Warm-up for Full Accuracy
10 min
Altitude
Two point calibration required after change in altitude of 2000 feet
Humidity
0 to 95%, non-condensing
Range
5 to 100%
Resolution
0.1%
Stability (24 hrs)
± 0.3%
Linearity
±0.2%
Cross Sensitivity
±0.2% in XC mode.
Input Pressure
1 to 75 psi -0.03 to 1.3 psi -0.03 to 1.3 psi
Flow
50 to 500 ml/min 0 to 250 ml/min pump on
50 to 500 ml/min pump off
0 to 250 ml/min pump on
50 to 500 ml/min pump off
Response Time
1 second at 350 ml/min, electronic Filter setting 0 to 6. 150 ms at 250 ml/min, electronic Filter setting 0 to 3 150 ms at 250 ml/min, electronic Filter setting 0 to 3
Alarms (4)
Low Flow
Oxygen A

Oxygen B

System Check
Relays
Form C (SPDT), 5 A, 250 VAC rating.
Analog Output
0 – 1 V, 1V = 100%.
4 – 20 mA programmable from front panel
Sample Inlet
CPC O-ring quick connects, 1/8 “ flex tubing barbs std.
Sensor Power Requirements
0.8 A typical
12 ± 0.6 VDC

2.5 A max
External Power Supply
100 to 250 VAC
47 to 63 Hz
Dimensions (W x H x D)
7.5x3.0x11.0 in
190x76x280
mm
7.5x3.0x11.0 in
190x76x280
mm
7.5x3.0x14.0 in
190x76x356
mm
Weight Instrument
4 Pound
1.8
Kilogram